2.14.18 Printer Sensor Test (Menu code 1865)
(MENU -> 8. SCALE CONFIG -> 6.Test -> 5. Printer Sensor )
Printer Sensor Test Items
Test Items Description
1 Peel-off
To test that peel-off sensor is properly work.
2 Head-up
To test that TPH is opened or not
3 Gap
To show real time-sensoring Gap value.
4 Peel
To show real time-sensoring peel value.
2.14.19 Memory Information (Menu code 1866)
(MENU -> 8. SCALE CONFIG -> 6.Test -> 6. Memory Information )
2.14.20 Firmware Version (Menu code 1867)
(MENU -> 8. SCALE CONFIG -> 6.Test -> 7. Firmware Version )
User may exit from this menu, using “X/ESC”
key.
To test printer sensor, press “5” on Test menu
screen. The scale shows the condition of current
printer sensor.
PRINTER SENSOR TEST (1/2)
Peel-off : [UNLOCKED]
Head-up : [CLOSED ]
To see memory information, press “6” on Test
menu screen. The display shows current memory
size. 0 indicates 1MB.
MEMORY INFORMATION (1/1)
012345
Chip Status : [00XXX]
Total Flash Size (MB) : 6
PRINTER SENSOR TEST (2/2)
Gap : [ 68]
Peel : [ 66]
User may exit from this menu, using “X/ESC”
key.
You can check firmware version of the scale.
DEV DESCRIPTION VERSION
#1 Scale Main F/W V1.03
#2 AD Module F/W V0.97
#3 Ethernet N/A

Table of Contents

Other manuals for CAS CL5000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAS CL5000 Series and is the answer not in the manual?

CAS CL5000 Series Specifications

General IconGeneral
Power SourceAC adapter
Auto CalibrationYes
Tare FunctionYes
Unit ConversionYes
InterfacesRS-232
Operating Temperature-10°C to 40°C
Weighing Unitskg, g
ApprovalNTEP, OIML