2.13.6 Label Size/Ticket Size (Menu code 1732)
(MENU -> 7. Print -> 3. Printer Hardware -> 2.Label Size)
2.13.7 Sensor Calibration (Menu code 1733)
(MENU -> 7. Print -> 3. Printer Hardware -> 3.Sensor Calibration)
2.13.8 Sensor & Motor (Menu code 1734)
(MENU -> 7. Print -> Printer Hardware -> 4. Sensor & Motor)
2.13.9 Print Intensity (Menu code 1735)
(MENU -> 7. Print -> 3. Printer Hardware -> 5.Print Intensity)
Enter any value from “0” to “20”.
Press “TEST” to test printing a label.
.
PRINT INTENSITY (1/1)
Printer Intensity (0-20) : [10]
[TEST] = Test Intensity
Enter appropriate values or “Yes” or “No” for
“PRINT METHOD TYPE”, “ACTIVE PEEL-OFF”,
ACTIVE REWIND MOTOR, and “LABEL PAPER”.
* If there is no gap on a label, set Label Paper to
0, if there a gap, set it to 1.
*When "Ticket Mode" is in "Print Mode", [Rewind
Motor] and [Labe Paper] do not work.
SENSOR&MOTOR (1/1)
Active Peel-off : [ Y ]
Active Rewind Motor : [ Y ]
Label Paper (0=No Gap, 1=Gap) : [ 1 ]
Enter values for “Width”, “Height”, “Gap Length”.
If you press “TEST” key, height and gap length of
current label is measured.
* If it is Ticket Mode, “TICKET SIZE” is displayed,
and “TEST” key is not operated.
* If it is Label mode and Continuous Label Paper,
“TEST” key is not operated. And "End Margin"
instead of "Gap Length" shows up.
LABEL SIZE (1/1)
Width :[60]mm
Height:[40]mm
Gap Length:[ 2]mm
Enter appropriate values for “Gap”, “Peel”, “Out of
Paper.
* If you press TEST key, Gap and Peel values are
adjusted automatically.
* If it is Ticket mode, “Gap” value is not saved.
SENSOR CALIBRATION (1/1)
Gap :[128]
Peel:[128]
[TEST]=Auto Calibration
TICKET SIZE (1/1)
Width :[60]mm
Feed : [20]mm
End Margin :[ 5]mm
SENSOR CALIBRATION (1/1)
Gap (Rcpt):[128]
Peel:[128]
[TEST]=Auto Calibration