2.1 PLU Programming
You can set 45 items for a PLU as below table and if you do not want to use
some items, you can prohibit those items in menu code:1144.
< PLU ITEM>
No Item Description
1 Department Department No.
2
PLU No
PLU No.
3 PLU Type Select PLU type among By Weight, By Count or By-PCS
4 Name 1 Enter name 1 of item. Maximum 40 characters.
5 Name 2 Enter name 2 of item. Maximum 40 characters.
6 Name 3 Enter name 3 of item. Maximum 40 characters.
7 Group No. Select group number. This value can be from 0 to 99.
8 Label No. (0~99) (0=Do not use Label No.), Label Formats “1~12”.
If Global Setting is YES, it is not shown.
9 Aux. Label No. (0~99) (0=Do not use Label No.), Label Formats “1~12”.
This function prints aux. label as saved number of label number
10 Origin No. (0~500) 0=Do not use origin.
11
Unit Weight Unit weight of Price(No.19) (1:unit price for 1lb,2:unit price for
1/2lb,3:unit price for 1/4lb,4:unit price for 1kg,5:unit price for 100g)
12
Fixed Weight
The weight is fixed regardless of item
13 Prefix Enter serial code for PLU (Greece version of CL5000 series)
14 Item code Item code
15 Use Fixed Price Type You can set wheter use Fixed Price or not
16
Pieces
(0-999) Set the number for By-PCS PLU
17
Quantity Symbol ID
(0~8) Set symbol of PCS or Count
18 Fixed price Price is fixed regardless of weight or pcs
19 (Unit) Price This value can be from 0 to 999999.
20 Special Price It can be unit price by using Special key.
21 Tax No. Enter tax number. This value can be from 0 to9
22
Tare / Tare No.
You can enter tare weight manually or enter No. of tare data.
(By-weight PLU)
23
% Tare
0~99.99 You can enter tare weight as percentage of item. If
you set it to 20%, 20% of item is tare weight.
24
Tare % Limit
0~99.99 You can enter tare limit.
%tare <= % limit -> Gross weight is printed
%tare > % limit -> Net weight is printed