© Cesab 8 – 31 T Code(s): 841, 842, 843
Repair manual: Troubleshooting Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
3:582
The transistor
regulator's output
for power supply
has the wrong
voltage level.
Everything is
stopped at once,
the parking brake
is activated, and
the main
contactor opens
1: Low power
consumption
or break
2: Short circuit in
power stage
1: Check wiring and component
after a break (main contactor,
lowering valve, brake, pump
contactor)
Disconnect the battery
Visually check the wiring
harness
Using instruments, check that
there is no break in any wire
Check the Ohms and the
Amperes of the component,
compare them to the setpoint
values, and replace the unit if
they are outside the accepted
range.
Reconnect the battery. Measure
and check the voltage for the
activated functions.
2: Replace T1
3:583
Internal transistor
regulator voltage
supply has not
been switched on.
Everything is
stopped at once,
the parking brake
is activated, and
the main
contactor opens
1: Defective
RPM sensor
2: Defective
motor control
1: Defective RPM sensor
Check cables and connectors
after interruption
Replace the speed sensor
2: Replace T1