2-207
Catalyst 3750-X and 3560-X Switch Command Reference
OL-21522-02
Chapter 2 Catalyst 3750-X and 3560-X Switch Cisco IOS Commands
hw-module
Examples This example shows how to enable OBFL on a Catalyst 3750-X-only switch stack and to specify that all
the hardware-related messages on stack member 4 are stored in the flash memory when this command
is entered on the stack master:
Switch(config)# hw-module module 4 logging onboard
This example shows how to enable OBFL on a standalone switch and to specify that only severity 1
hardware-related messages are stored in the flash memory of the switch:
Switch(config)# hw-module module 1 logging onboard message level 1
You can verify your settings by entering the show logging onboard onboard privileged EXEC
command.
Related Commands Command Description
clear logging onboard Removes the OBFL data in the flash memory.
show logging onboard onboard Displays OBFL information.