2-482
Catalyst 3750-X and 3560-X Switch Command Reference
OL-21522-02
Chapter 2 Catalyst 3750-X and 3560-X Switch Cisco IOS Commands
remote-span
remote-span
Use the remote-span VLAN configuration command on the switch stack or on a standalone switch to
configure a VLAN as a Remote Switched Port Analyzer (RSPAN) VLAN. Use the no form of this
command to remove the RSPAN designation from the VLAN.
remote-span
no remote-span
Syntax Description This command has no arguments or keywords.
Defaults No RSPAN VLANs are defined.
Command Modes VLAN configuration (config-VLAN)
Command History
Usage Guidelines You can configure RSPAN VLANs only in config-VLAN mode (entered by using the vlan global
configuration command), not the VLAN configuration mode entered by using the vlan database
privileged EXEC command.
If VLAN Trunking Protocol (VTP) is enabled, the RSPAN feature is propagated by VTP for VLAN-IDs
that are lower than 1005. If the RSPAN VLAN ID is in the extended range, you must manually configure
intermediate switches (those in the RSPAN VLAN between the source switch and the destination
switch).
Before you configure the RSPAN remote-span command, use the vlan (global configuration) command
to create the VLAN.
The RSPAN VLAN has these characteristics:
No MAC address learning occurs on it.
RSPAN VLAN traffic flows only on trunk ports.
Spanning Tree Protocol (STP) can run in the RSPAN VLAN, but it does not run on RSPAN
destination ports.
When an existing VLAN is configured as an RSPAN VLAN, the VLAN is first deleted and then recreated
as an RSPAN VLAN. Any access ports are made inactive until the RSPAN feature is disabled.
Release Modification
12.2(53)SE2 This command was introduced.

Table of Contents

Other manuals for Cisco Catalyst 3560X-24P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3560X-24P and is the answer not in the manual?

Cisco Catalyst 3560X-24P Specifications

General IconGeneral
Device TypeSwitch
Enclosure TypeRack-mountable
Ports24
Power over Ethernet (PoE)Yes
StackingYes
RAM512 MB
Flash Memory128 MB
Power DeviceInternal power supply
Voltage Required100-240V AC
Operating Temperature32 to 113°F (0 to 45°C)
Jumbo Frame SupportYes
Routing ProtocolOSPF, RIP, EIGRP
Remote Management ProtocolSNMP, SSH, Telnet
FeaturesQuality of Service (QoS), VLAN support, Access Control Lists (ACLs)
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z
Operating Humidity10% to 90% non-condensing
ManagementSNMP
ModelCisco Catalyst 3560X-24P
Uplink Ports4