2-573
Catalyst 3750-X and 3560-X Switch Command Reference
OL-21522-02
Chapter 2 Catalyst 3750-X and 3560-X Cisco IOS Commands
show env
This is an example of output from the show env stack command on a stack master:
Switch> show env stack
SWITCH: 1
FAN 1 is OK
FAN 2 is OK
PS-FAN1 is OK
PS-FAN2 is OK
TEMPERATURE is OK
Temperature Value: 27 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 49 Degree Celsius
Red Threshold : 59 Degree Celsius
POWER is OK
RPS is AVAILABLE
<output truncated>
This example shows how to display the temperature value, state, and the threshold values on a standalone
switch.
Table 2-33 describes the temperature states in the command output.
Switch> show env temperature status
Temperature Value: 33 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 65 Degree Celsius
Red Threshold : 75 Degree Celsius
Related Commands
Ta b l e 2-33 States in the show env temperature status Command Output
State Description
Green The switch temperature is in the normal operating range.
Yellow The temperature is in the warning range. You should check the external temperature
around the switch.
Red The temperature is in the critical range. The switch might not run properly if the
temperature is in this range.
Command Description
power supply Configures and manages the power supply modules on the switch.