2-740
Catalyst 3750-X and 3560-X Switch Command Reference
OL-21522-02
Chapter 2 Catalyst 3750-X and 3560-X Cisco IOS Commands
show power inline
Gi3/0/9 NO 0.0
Gi3/0/10 NO 0.0
<output truncated>
This is an example of output from the show power inline police command on a Catalyst 3750-X switch.
Table 2-47 describes the output fields.
Switch> show power inline police
Module Available Used Remaining
(Watts) (Watts) (Watts)
------ --------- -------- ---------
1 370.0 0.0 370.0
3 865.0 864.0 1.0
Admin Oper Admin Oper Cutoff Oper
Interface State State Police Police Power Power
--------- ------ ----------- ---------- ---------- ------ ------
Gi1/0/1 auto off none n/a n/a 0.0
Gi1/0/2 auto off log n/a 5.4 0.0
Gi1/0/3 auto off errdisable n/a 5.4 0.0
Gi1/0/4 off off none n/a n/a 0.0
Gi1/0/5 off off log n/a 5.4 0.0
Gi1/0/6 off off errdisable n/a 5.4 0.0
Gi1/0/7 auto off none n/a n/a 0.0
Gi1/0/8 auto off log n/a 5.4 0.0
Gi1/0/9 auto on none n/a n/a 5.1
Gi1/0/10 auto on log ok 5.4 4.2
Gi1/0/11 auto on log log 5.4 5.9
Gi1/0/12 auto on errdisable ok 5.4 4.2
Gi1/0/13 auto errdisable errdisable n/a 5.4 0.0
<output truncated>
In the previous example:
• The Gi1/0/1 port is shut down, and policing is not configured.
• The Gi1/0/2 port is shut down, but policing is enabled with a policing action to generate a syslog
message.
• The Gi1/0/3 port is shut down, but policing is enabled with a policing action is to shut down the port.
• Device detection is disabled on the Gi1/0/4 port, power is not applied to the port, and policing is
disabled.
• Device detection is disabled on the Gi1/0/5 port, and power is not applied to the port, but policing
is enabled with a policing action to generate a syslog message.
• Device detection is disabled on the Gi1/0/6 port, and power is not applied to the port, but policing
is enabled with a policing action to shut down the port.
• The Gi1/0/7 port is up, and policing is disabled, but the switch does not apply power to the connected
device.
• The Gi1/0/8 port is up, and policing is enabled with a policing action to generate a syslog message,
but the switch does not apply power to the powered device.
• The Gi1/0/9 port is up and connected to a powered device, and policing is disabled.
• The Gi1/0/10 port is up and connected to a powered device, and policing is enabled with a policing
action to generate a syslog message. The policing action does not take effect because the real-time
power consumption is less than the cutoff value.
• The Gi1/0/11 port is up and connected to a powered device, and policing is enabled with a policing
action to generate a syslog message.