ATA Voice Field Reference
Regional page
Cisco Small Business ATA Administration Guide 151
B
Miscellaneous section
Set Local Date
(mm/dd)
Sets the local date (mm stands for months and dd stands
for days). The year is optional and uses two or four digits.
Set Local Time (HH/
mm)
Sets the local time (hh stands for hours and mm stands for
minutes). Seconds are optional.
Time Zone Selects the number of hours to add to GMT to generate the
local time for caller ID generation. Choices are GMT-12:00,
GMT-11:00,, GMT, GMT+01:00, GMT+02:00, ,
GMT+13:00.
The default is GMT-08:00.
FXS Port
Impedance
Sets the electrical impedance of the FXS port. Choices are
600, 900, 600+2.16uF, 900+2.16uF, 270+750||150nF,
220+850||120nF, 220+820||115nF, or 200+600||100nF.
The default is 600.
NOTE For New Zealand impedance (370+620||310nF), use
270+750||150nF.