15) IVC: V Series panels, Trunking, Directs, Agent-IC, LQ.
16) AES67: data and audio connection between the E-IPA-HX card and the
IP Transceivers (IPTs).
Functionality and IP ports can be combined, but Clear-Com recommends
certain rules for set up to avoid loss of functionality and IP clashes.
12.2.1 Network setup for Clear-Com IVC functionality (V
Series panels, Directs, Trunks, LQ and Agent-IC)
When configuring IVC functionality you must allocate a static IP address to this
connection.
Note: You must configure the subnet mask to match your network topology
when using a static IP address. Contact your network administrator for
more information.
When using IVC functionality, the recommended setup is to combine IVC and
administration functions on the same IP address (default setting).