Page 24
Each E-MADI64 card set comprises:
A front card with pin reset and various status indicators (including
channel quantity, sample rate, power and diagnostic (active and error)
indicators).
A rear card with a MADI fiber connector, MADI input and output coaxial
cable connectors, and coaxial Video black and burst / Tri Level HD /
Word clock sync input.
See also 6 E-MADI64 card for more information
3.4.5 IVC-32 IP interface card
The IVC-32 interface allows the Eclipse HX matrix to connect to IP enabled V-
Series panels, other matrices and Concert users using an IP network.
Each IVC-32 interface comprises:
A front card with a reset button and various status indicators.
A rear card with eleven RJ-45 ports giving eight E1/T1 ports (not used),
DECT sync in and out (not used) and a LAN port for IP connectivity.
Each IVC-32 front card has status LEDs for power, port activity and LAN status.
The LAN indicators show whether there is a LAN connection and the IP activity
on the LAN port.
3.4.5.1 IVC-32 Redundant Card
You can add an IVC-32 Redundant Card that provides fail-over redundancy for
one or more IVC-32 Cards in the matrix.
An IVC-32 Card will fail-over to the IVC-32 Redundant Card under the following
conditions:
•All configured VoIP ports are unconnected for longer than 90 seconds.
• The IVC-32 Card is detected as absent from the VME backplane.
• It is requested via the EHX Event Log.
A switch back from a redundant card back to a failed card only occurs under the
following condition:
The redundant card has failed. If the original card is still in error, then it
will switch back and forward until corrective action is taken.
3.4.6 LMC-64 metering card
The LMC-64 interface allows the Eclipse HX-Delta to provide Production Maestro
Pro (routing software) clients with audio level metering of partylines
(conferences) and four-wire ports over an IP network. The card supports both
direct and trunk connections.