7.4.3.1 Single Card Set Redundant System: fiber redundancy
In all fault cases involving cable faults or loss of nodes on the ring the remaining
nodes may experience audio breaks or disturbances and loss of crosspoint
information or data.
When a ring with non-adjacent failures sub-divides into two sub-rings, audio and
data from the failed nodes will not be available to the nodes in either sub-ring,
audio will continue to be available to nodes within the same sub-ring but data
may still be available to all nodes that are still functioning if there is an intact,
independent Ethernet connection to those nodes.
If a matrix, connected as a node of the fiber-optic link is reset, powered down or
failed this will constitute a lost or failed node on the ring and this node will
experience audio breaks or disturbances and loss of crosspoint information or
data for up to 5 seconds after the fault condition is cleared or repaired.
An example of how a system with multiple matrices would be wired together is
shown in Figure 7-5: Example fiber-optic connection setup in this
document.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Clear-Com eclipse HX-Delta and is the answer not in the manual?

Clear-Com eclipse HX-Delta Specifications

General IconGeneral
BrandClear-Com
Modeleclipse HX-Delta
CategoryIntercom System
LanguageEnglish

Related product manuals