InteliDrive DCU Industrial 3.4.0 Global Guide
278
Value group Statistics Related FW 3.4.0
Resolution [units] 1 [-]
Comm object 8231 Related applications AS, SS
Description
There are two Statistics registers Memo1 and Memo2. Those statistic values are based on Logical Analog
Input Memory1 or Memory2 value in the time of Logical Binary input Memo1 Trigger or Memo2 Trigger
rising edge. Both statistics values is possible to modify in InteliMonitor – Set Statistics command.
Memo2
6 back to List of values
Value group Statistics Related FW 3.4.0
Resolution [units] 0.1 [/nm]
Comm object 11321 Related applications AS, SS
Description
Momentary average fuel consumption per nautical mile. It is available, if both FUELCONSUMP (PAGE 237) and
BOATSPEED (PAGE 1) are configured.
MomAvgFlCon L
6 back to List of values