InteliDrive DCU Industrial 3.4.0 Global Guide
253
Warning Indication only (no engine stop)
Shutdown Fast engine stop
Cooldown Engine stop with cooling period
Fail sensor Measured value is out of sensor characteristics.
Warning+BW Indication + Broken wire detection
Shutdown+BW Shut down + Broken wire detection
Warning + Fls Warning is activated in the case of sensor fail as well
Shutdown + Fls Shut down is activated in the case of sensor fail as well
Sd override This protection stays active in the case of Sd override is activated.
Alarm only Only Alarm list indication, disappear without confirmation
HistRecOnly History record only
Protection types
8.1.5 Values
What values are:
Values (or quantities) are analog or binary data objects, measured or computed by the controller, that are
intended for reading from the controller screen, PC, MODBUS, etc. Values are organized into groups according
to their meaning.
List of value groups
Basic Settings 255
Engine Values 256
Analog CU 264
Binary CU 267
Log Bout 268
Info 270
Statistics 276
Aftertreatment 279
For full list of values go to the chapter List of values (page 254).