Linea Lite GigE Series Camera Operational Reference 89
counterResetSource must be set to CounterEnd. When the counterValue feature reaches the
counterDuration value an event is generated and the counter is reset to 00, then continues.
Example: CounterStartSource = EVENT and Signal (Edge Base)
Countermode = OFF
Counter is
IDLE
Counter
Overflow
CounterEnd Event Generated
Counter is
Active
CounterStartSource = EVENT
or
Signal
(Edge Base )
Counter
Trigger Wait
Counter is incrementing
Countermode = Active
CounterResetSource
= OFF
CounterResetSource = Event
Counter Reset CMD
Counter
Completed
CounterResetSource = CounterEnd (Itself)
CounterStartSource = EVENT and Signal (Edge Base )
CounterResetSource
= Event
(Itself)
0
Figure 73: Example: CounterStartSource = EVENT and Signal (Edge Base)
Example: CounterStartSource = Signal (Level Base) Example 1
Countermode = OFF
Counter is
IDLE
CounterEnd Event Generated
CounterStartSource
=
Signal (Level Base )
Counter
Trigger Wait
Counter Register
Countermode = Active
Counter
Completed
CounterResetSource =
CounterEnd (Itself)
CounterStartSource = Signal (Level Base ) Example 1
Wait
ActiveActive
CounterTriggerActivation =
LevelLow
Counter STATUS
0
10
65
0
9
Tick in
CounterEventSource
Active
1
1
Figure 74: Example CounterStartSource = Signal (Level Base)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dalsa Linea Lite GigE Series and is the answer not in the manual?

Dalsa Linea Lite GigE Series Specifications

General IconGeneral
BrandDalsa
ModelLinea Lite GigE Series
CategoryDigital Camera
LanguageEnglish

Related product manuals