EasyManuals Logo
Home>Danfoss>Air Compressor>Turbocor TT Series

Danfoss Turbocor TT Series User Manual

Danfoss Turbocor TT Series
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #111 background imageLoading...
Page #111 background image
4.13 Terminal Block Fuse Replacement
TTS300/TGS230compressorshaveclassTfast-actingfusesinstalledintheTerminalBlock.
Figure 4-91 Terminal Block Fuse
4.13.1 Verification of Terminal Block Fuse
1. IsolatethecompressorpowerasdescribedinSection1.8ElectricalIsolationonpage22.
2. Setthemultimeterforresistancemeasurement.
3. Placeone(1)meterprobethelinesideofthefuseandtheotherprobeontheloadside.RefertoFigure
4-92TerminalBlockFuseTest.Theresistanceshouldbenogreaterthan2Ω.
Figure 4-92 Terminal Block Fuse Test
4. Continuefortheremainingtwo(2)fuses.
5. Replaceanyfusesthatreadopenorhavearesistancegreaterthan2Ω.
4.13.2 Terminal Block Fuse Removal and Installation
4.13.2.1 Terminal Block Fuse Removal
1. IsolatethecompressorpowerasdescribedinSection1.8ElectricalIsolationonpage22.
2. Removethe5/16-18fasteneronthelinesideofthefuse.
3. Removethe5/16-18nutfromtheloadsideofthefuse.
4. Removethefuse.
M-SV-001-EN Rev. H-1/23/2023 Page 111 of 294

Table of Contents

Other manuals for Danfoss Turbocor TT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss Turbocor TT Series and is the answer not in the manual?

Danfoss Turbocor TT Series Specifications

General IconGeneral
BrandDanfoss
ModelTurbocor TT Series
CategoryAir Compressor
LanguageEnglish

Related product manuals