Appendix A Acronyms/Terms
Table A-1 Acronyms/Terms
Acronym/Term Definition
AC AlternatingCurrent
AFT Ascendingfaulttriggering
Alarms Alarmsindicateaconditionatthelimitofthenormaloperatingenvelope.CompressoralarmswillstillallowtheCompressortorun,
butspeedisreducedtobringthealarmconditionunderthealarmlimit.
ASHRAE AmericanSocietyofHeatingRefrigerationandAir-ConditioningEngineers(www.ashrae.org).
Backplane APCBforthepurposeofpowerandcontrolsignaltransmission.Manyothercomponentsconnecttothisboard.
BMCC BearingMotorCompressorController.TheBMCCisthecentralprocessorboardoftheCompressor.Basedonitssensorinputs,it
controlsthebearingandmotorsystemandmaintainsCompressorcontrolwithintheoperatinglimits.
CavitySensor NTCtemperaturesensorlocatedbehindtheBackplaneforthepurposeofsensingmotor-coolingvaportemperature.Provides
overheatprotectiontomotorwindings.
CE CEmarkingensuresthefreemovementwithintheEuropeanmarketofproductsthatconformtotherequirementsofEUlegislation
(e.g.,safety,healthandenvironmentalprotectionandisakeyindicatorofaproduct’scompliancewithlegislation.
TheCEmarkingisaffixedbymanufacturerstotheirproducts.ByplacingCEmarkingonaproduct,manufacturers
declareontheirsoleresponsibilitythattheproductscomplywithallthelegalrequirementsinforceinEurope.
Citation:EuropeanCommission;Directorate-GeneralforEnterpriseandIndustry;ww.ec.europa.eu/CEmarking.
CIM/I/O-
board
CompressorInterfaceModule;thepartofthecompressorelectronicswheretheuserconnectsallfieldconnectionwiringsuchasRS-
485,EXV,andanalog/digitalwiring.AlsoknownastheI/Oboard.
DC DirectCurrent
DC-DC DCtoDCConverter
DFT Descendingfaulttriggering
DIN GermanInstituteforStandardization
EEPROM ElectricallyErasableProgrammableRead-OnlyMemory
EMF ElectromotiveForce
EPR Evaporatorpressureregulating
ESD ElectostaticDischarge
EXV ElectronicExpansionValve
HV HighVoltage
IGV Inletguidevane
INS Instantfaulttriggering
I/O Input/output
k/V Kilovolt
LED LightEmittingDiode
LOTO Lockout/Tagout
NTC NegativeTemperatureCoefficient
OEM OriginalEquipmentManufacturer
ORFS O-ringfaceseal
PCB PrintedCircuitBoard
PDF PortableDocumentFormat
PWM Pulsewidthmodulation
P/T Pressure/Temperature
RFT Rangefaulttriggering
M-SV-001-EN Rev. H-1/23/2023 Page 279 of 294

Table of Contents

Other manuals for Danfoss Turbocor TT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss Turbocor TT Series and is the answer not in the manual?

Danfoss Turbocor TT Series Specifications

General IconGeneral
BrandDanfoss
ModelTurbocor TT Series
CategoryAir Compressor
LanguageEnglish

Related product manuals