Figure 4-258 Compressor Monitor Tool
Table 4-46 Bearing Amperage Nominal Ranges
Bearing Position Force Range
AxialForce -1.5to1.5Amp(TTS300&TGS230=-2to0Amp)
FrontXForce -1.5to1.5Amp
FrontYForce -1.5to1.5Amp
RearXForce -1.5to1.5Amp
RearYForce -1.5to1.5Amp
4.29.4 Bearing Power Feedthrough Removal and Installation
Thestepsdepictedinthissectionwillapplytoeitherthefrontorrearfeedthrough.
4.29.4.1 Bearing Power Feedthrough Removal
1. IsolatecompressorpowerasdescribedinSection1.8ElectricalIsolationonpage22.
2. Isolatethecompressorandrecovertherefrigerantaccordingtoindustrystandards.RefertoSection3.1
RefrigerantContainmentonpage41.
3. RemovetheServiceSideCover.RefertoSection4.1.3.1ServiceSideCoverRemovalandInstallationon
page54.
4. PulltheSerialDriverModuleoutofitsslot.Makesureyoudonotdamagetheconnectorpins.Keepthe
moduleinasafeplace.RefertoSection4.26.4SerialDriverRemovalandInstallationonpage218.
NOTE
Referto1.9HandlingStaticSensitiveDevicesforproperESDhandlingofelectroniccomponents.
M-SV-001-EN Rev. H-1/23/2023 Page 233 of 294

Table of Contents

Other manuals for Danfoss Turbocor TT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss Turbocor TT Series and is the answer not in the manual?

Danfoss Turbocor TT Series Specifications

General IconGeneral
BrandDanfoss
ModelTurbocor TT Series
CategoryAir Compressor
LanguageEnglish

Related product manuals