Operator info Additional information
Engine start not possible in
SWBD
While the controller is under switchboard control, operator
actions cannot be performed from the controller
interfaces.
Engine start unblocked The Block engine start function is not active.
Engine stop not possible in
SWBD
While the controller is under switchboard control, operator
actions cannot be performed from the controller
interfaces.
GB close blocked
The Block GB close function is active. An open breaker
cannot be closed.
GB close not possible in
SWBD
While the controller is under switchboard control, operator
actions cannot be performed from the controller
interfaces.
GB close cancelled The GB close was cancelled by a GB open command.
GB close not possible in
SWBD
While the controller is under switchboard control, operator
actions cannot be performed from the controller
interfaces.
GB close unblocked The Block GB close function is not active.
GB is closed The Generator breaker is closed.
GB is de-loading The Generator breaker is currently de-loading.
GB is open The Generator breaker is open.
GB is synchronising The Generator breaker is synchronising.
GB open and stop not
possible in SWBD
While the controller is under switchboard control, operator
actions cannot be performed from the controller
interfaces.
GB open cancelled The GB open was cancelled by a GB close command.
GB open not possible in
SWBD
While the controller is under switchboard control, operator
actions cannot be performed from the controller
interfaces.
Mode change locked
It is not possible to change to REMOTE or LOCAL mode
while the controller is under switchboard control.
Not under local control
The action cannot be performed unless the controller is in
LOCAL mode.
You can remove latches
There are acknowledged latched alarms in the alarm list
that can be reset.
SCB close blocked
The Block SCB close function is active. An open breaker
cannot be closed.
SCB close cancelled The SCB close was cancelled by a SCB open command.
SCB close not possible in
SWBD
While the controller is under switchboard control, operator
actions cannot be performed from the controller
interfaces.
SCB close unblocked The Block SCB close function is not active.
SCB open cancelled The SCB open was cancelled by a SCB close command.
SCB open not possible in
SWBD
While the controller is under switchboard controller,
operator actions cannot be performed from the controller
interfaces.