EasyManuals Logo

Dell Networking N4000 Series User Manual

Dell Networking N4000 Series
1460 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1008 background imageLoading...
Page #1008 background image
1008 Configuring Data Center Bridging Features
It is recommended that the maximum bandwidth be configured to be greater
than the minimum bandwidth or the weight or be configured to 0 (unlimited
burst size).
console(config-if-Te1/0/1)#traffic-class-group max-bandwidth 50 90 20
9. Set the Scheduler Modes for the TCGs
This step enables strict priority scheduling on TCGs. Strict priority
scheduling on multiple TCGs prioritizes traffic from the highest numbered
TCG for transmission first. Strict priority scheduling on a single TCG selects
that TCG for transmission before the WDRR TCGs. Use the 'no' command
to disable strict priority scheduling. It is recommended that all CoS queues
enabled for strict priority scheduling be assigned to a single TCG other than
TCG0. This scheme allows a larger number of priorities to be configured as
strict priorities.
console(config-if-Te1/0/1)#traffic-class-group strict 2
To show the weight, minimum bandwidth, maximum bandwidth, and
scheduler modes of the TCGs, use the following command:
console#show interfaces traffic-class-group tengigabitethernet 1/0/1
Interface...................................... Te1/0/1
Traffic Class Min. Max
Group Bandwidth Bandwidth Weight Scheduler Type
------------ --------- ------------ ------ --------------
0 10 50 30 Weighted Round Robin
1 50 90 70 Weighted Round Robin
2 0 20 0 Strict

Table of Contents

Other manuals for Dell Networking N4000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Networking N4000 Series and is the answer not in the manual?

Dell Networking N4000 Series Specifications

General IconGeneral
LayerLayer 3
Switching CapacityUp to 1.28 Tbps
Operating Temperature0°C to 45°C (32°F to 113°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
SeriesN4000 Series
StackingUp to 12 units
Power SupplyDual, hot-swappable
ManagementWeb, CLI, SNMP
Humidity10% to 90% (non-condensing)

Related product manuals