940 Configuring Link Aggregation
Supported topologies and the way traffic is handled in these topologies is
explained in the following sections.
The MLAG component uses the keep-alive protocol to select a primary and a
secondary device. The primary switch owns the MLAG member ports on the
secondary device. It handles the control plane functionality of supported
protocols for the MLAG member ports on the secondary.
Peer-Link
The peer-link is a crucial for MLAG operation. The peer-link must be
configured on a port-channel interface. Only one peer-link aggregation group
is allowed per peer switch and this peer-link is shared by all instances of
MLAG running on the two peer switches. The peer-link must NOT have
spanning tree enabled.
The peer-link is used for the following purposes:
To transport keep-alive messages to the peer.
To sync FDB entries learned on MLAG interfaces between the two MLAG
peer switches.
To forward STP BPDUs and LACPDUs received on secondary MLAG
member ports to the primary MLAG switch.
To send interface events related to MLAG interface and member ports
that occur on the secondary switch to the primary switch.
To transfer MLAG control information between the primary and
secondary MLAG switches.
Support a redundant forwarding plane in the case that all member ports of
an MLAG interface are down on an MLAG peer. In this case, traffic
received on the peer switch destined to the MLAG peer with the downed
ports is sent over the peer-link to the peer MLAG switch for forwarding to
the partner switch.
The peer-link is not utilized for partner traffic unless all LAG links connected
to an MLAG partner on a single MLAG peer are disrupted. It is strongly
recommended that the MLAG peer LAG consist of multiple physical links
with sufficient bandwidth to carry all traffic expected to be carried by either
of the MLAG peers.

Table of Contents

Other manuals for Dell Networking N4000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Networking N4000 Series and is the answer not in the manual?

Dell Networking N4000 Series Specifications

General IconGeneral
LayerLayer 3
Switching CapacityUp to 1.28 Tbps
Operating Temperature0°C to 45°C (32°F to 113°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
SeriesN4000 Series
StackingUp to 12 units
Power SupplyDual, hot-swappable
ManagementWeb, CLI, SNMP
Humidity10% to 90% (non-condensing)