8-2
Ultron DPS Series
8.1 LCD Display Hierarchy
EVENT LOG
S/ N
FW VERSION
STATISTICS
ADVANCED
BATTERY
LOCAL
OUTPUT
BYPASS
CONTROL & TEST
CHARGER
PARALLEL
OTHERS
MAINS/ BYPASS
OUTPUT
BATTERY
STS T(°C)
INVERTER
MEASURE
MAINTENANCE
(Level 3)
(Level 3)
(Level 4)
(Level 4)
(Level 5)
(Level 5) (Level 5) (Level 5)
(Level 5)
(Level 5) (Level 5) (Level 5)
(Level 5)
*
1
FREQ(Hz)
Vphase(V)/ Vline(V)/ Iphase(A)/
VOLT(V)/ CURRENT(A)
FREQ(Hz)/ LOAD(%)/ KVA/ KW
Vphase(V)/ Vline(V)/ CURRENT(A)/
STATUS/ TEST RESULT/ BAT #1 T(°C)/ BAT
VOLT(V)/ CURRENT(A)/ CAPACITY(%)/
#2 T(°C)/ BAT #3 T(°C)/BAT #4 T(°C)/
DISPLAY/
SYSTEM/
PWR UNIT #N
ON BYPASS COUNTS/
ON BAT COUNTS/
OPERATION TIME(Y-D-H-M)
<002>.../
<001>.../
<003>...
CLR STATISTICS/
FW UPGRADE/
CLR EVENT LOG/
FORCE BYP TO INV/
OTHERS
PFC HC T(°C)/ INV R/ S/ T HS T(°C)
MAIN MENU
MAIN SCREEN
(Level 1) (Level 1)
(Level 2)
(Level 3)
(Level 4)
(Level 5)
(Level 5)
(Level 5)
(Level 5)
(Level 5)
(Level 5)
(Level 5)
*
1
*
1
*
1
*
1
*
1
*
1
FREQ RANGE
VOLT RANGE/
TYPE(AH)/
BAT RATING VOLT(V)/
BAT STRINGS/
COMMON BAT/
BAT CUT OFF VOLT(V)/
TEST DURATION(MIN)/
INSTALL DATE(Y-M-D)/
TEST FAIL VOLT(V)/
NEXT REPLACE DATE(Y-M-D)
FLOAT CHARGE VOLT (V)/
BOOST CHARGE VOLT (V)/
CHARGE CURRENT (A)/
AUTO BOOST CHARGE/
AUTO BOOST CHARGE PERIOD (MONTH)/
AUTO BOOST CHARGE TIME (HOUR)
PARALLEL ID/
PARALLEL GROUP/
VOLT(V)/ FREQ(Hz)/
ECO/ FREQ CONV/
REDUNDANCY(PWR UNIT)/
ASYNC TRANSFER TIME(MS)/
DC TO AC DELAY TIME(S)
BAT AUTO TEST/ BUZZER/
SILENCE ON & OFF/
FORCE BOOST CHARGE/
MANUAL BAT TEST/
CLR BAT TEST RESULT/
BUZZER & LED TEST/
RESET MODULE
DATE FORMAT/
DATE(Y-M-D) & TIME/
SERIAL COM ID/
ADMIN PASSWORD/
LCD CONTRAST/
USER PASSWORD/
LANGUAGE
DUST FILTER DUE DATE(Y-M-D)
DUST FILTER INSTALLATION/
(Level 5)
ALARM/ FAULT
INFORMATION
UPS SETUP &
CONTROL
*
1
*
1
*
2
*
2
*
2
*
2
*
2
*
2
(Figure 8-1: LCD Display Hierarchy)
NOTE:
1. *1 means that ADMINISTRATOR password is needed and *2 means that USER
password is needed. For password information, please refer to 8.3 Password Entry.
2. All unit No., UPS status, date, time, and event No. (e.g. 004) shown in the LCD diagrams
presented in 8. LCD Display and Settings are for reference only. Actual readings
depend on the operation of the UPS.

Table of Contents