OPERATOR’S MANUAL
ERROR
CODE
ERROR
PROBABLE CAUSE
CORRECTIVE ACTION
508
Road Temp Below Alarm
Value 1
Temperature has dropped below alarm threshold.
1.
Adjust alarm setting.
2.
Check sensor.
509
Road Temp Below Alarm
Value 2
Temperature has dropped below alarm threshold.
1.
Adjust alarm setting.
2.
Check sensor.
510 Road Temp Below Alarm
Value 3
Temperature has dropped below alarm threshold.
1.
Adjust alarm setting.
2.
Check sensor.
511
Digital Accessory 1 Active
1.
Adjust alarm setting.
2.
Check sensor.
512 Digital Accessory 1 High Sensor has reached the defined high alarm limit
value.
1.
Adjust alarm setting.
2.
Check sensor.
513
Digital Accessory 1 Low Sensor has reached the defined low alarm limit
value.
1.
Adjust alarm setting.
2.
Check sensor.
514
Digital Accessory 1
Shutdown
Digital accessory sensor has reached the defined
alarm limit and the control has been shutdown to
protect the system.
1.
Adjust alarm setting.
2.
Check sensor.
515 Digital Accessory High
Shutdown
Sensor has reached the defined high alarm
shutdown limit and the control has been shutdown
to protect the system.
1.
Adjust alarm setting.
2.
Check sensor.
516 Digital Accessory Low
Shutdown
Sensor has reached the defined low alarm
shutdown limit and the control has been shutdown
to protect the system.
1.
Adjust alarm setting.
2.
Check sensor.
517 Digital Accessory 2 Active
1.
Adjust alarm setting.
2.
Check sensor.
518 Digital Accessory 2 High Sensor has reached the defined high alarm limit
value.
1.
Adjust alarm setting.
2.
Check sensor.
519 Digital Accessory 2 Low Sensor has reached the defined low alarm limit
value.
1.
Adjust alarm setting.
2.
Check sensor.
520 Digital Accessory 2
Shutdown
Digital accessory sensor has reached the defined
alarm limit and the control has been shutdown to
protect the system.
1.
Adjust alarm setting.
2.
Check sensor.
521
Digital Accessory High
Shutdown
Sensor has reached the defined high alarm
shutdown limit and the control has been shutdown
to protect the system.
1.
Adjust alarm setting.
2.
Check sensor.
522
Digital Accessory Low
Shutdown
Sensor has reached the defined low alarm
shutdown limit and the control has been shutdown
to protect the system.
1.
Adjust alarm setting.
2.
Check sensor.
523
Hopper Low Hopper level is low.
1.
Fill hopper.
2.
Check sensor.
604
ECU Low Voltage
1.
Damaged CAN or module harness.
2.
Defective module
1.
Inspect CAN/module harness of the module for
damage.
2.
Inspect module for damage and replace, if
necessary.
605 ECU High Voltage
1.
Damaged CAN or module harness.
2.
Defective module
1.
Inspect CAN/module harness of the module for
damage.
2.
Inspect module for damage and replace, if
necessary.
606
Solenoid Low Voltage
1.
Damaged CAN or module harness.
2.
Blow module harness fuse.
3.
Defective module.
1.
Inspect CAN/module harness of the module for
damage.
2.
Inspect module harness fuse and replace, if
necessary.
3.
Inspect module for damage and replace if
necessary.
607 Solenoid Voltage with
Control Shutdown
Solenoid voltage is too high and the control system
has shutdown.
1. Voltage issue must be corrected before control
can resume.
140 / TROUBLESHOOTING
Flex4 Pro
TM
Control System
6010541 Rev A