Configure PSTN interfaces
Digi TransPort User Guide 256
Related CLI commands
Entity Instance Parameter Values Equivalent Web Parameter
ppp n metric 0-255 Metric
ppp n aodion 0-2
0=disabled
1=enabled
2=On and
return to service
immediately
Enable “Always On” mode of this
interface, On, On and return to
service immediately
ppp n immoos ON, OFF Put this interface “Out of Service”
when an always-on connection
attempt fails
ppp n aodi_dly 0-2147483647 Attempt to reconnect after s
seconds
ppp n aodi_dly2 0-2147483647 If an inhibited PPP interface is
connected, attempt to re-connect
after s seconds
ppp n pwr_dly 0-2147483647 Wait s seconds after power-up
before activating this interface
ppp n tband 0-4 Control when this interface can
connect using Time Band n
ppp n minup 0-2147483647 Keep this interface up for at least s
seconds
ppp n maxup 0-2147483647 Close this interface after s seconds
ppp n maxuptime 0-2147483647 if it has been up for m minutes in a
day
ppp n timeout 0-2147483648 if the link has been idle for s
seconds
ppp n timeout2 0-2147483648 Alternative idle timer for static
routes s seconds
ppp n rxtimeout 0-2147483648 if the link has not received any
packets for s seconds
ppp n maxneg 0-2147483648 if the negotiation is not complete in
s seconds
ppp n uplogmins 0-2147483647 Generate an event after this
interface has been up for m mins
ppp n dlwarnkb 0-2147483647 Issue a warning after n units