Enable and disable time bands for a PPP instance
Digi TransPort User Guide 489
Enable and disable time bands for a PPP instance
On the Configuration > Network > Timebands page, enabling and disabling time bands for a
particular PPP instance is controlled by the settings in a table having the following columns:
Interface
Lists the available PPP instances.
Enable
This column contains checkboxes; each checkbox controls whether or not time bands are
enabled for the PPP instance in the left-hand column of the row. Check the checkbox to
enable time bands for the associated PPP instance.
Timeband
Selects which of the four available time band instances should be associated with the PPP
instance.
Related CLI commands
The default state of this parameter is blank.
Entity Instance Parameter Values Equivalent Web Parameter
ppp n tband 0-3 Timeband