Configure X.25 parameters
Digi TransPort User Guide 544
4 Idle Timer Delay
Defines a time-out period after which data received from the DTE is assembled into a packet
and forwarded to the network. If the forwarding time-out is disabled, one or more characters
should be selected as data forwarding characters using parameter 3.
5 Ancillary Device Control
Determines method of flow control used by the PAD to temporarily halt and restart the flow of
data from the DTE during a call.
6 Suppression of PAD Service Signals
Determines whether or not the PAD> prompt and/or Service/Command signals are issued to
the DTE.
Option Description
0No data forwarding time-out
1 Data forwarding time-out in 20ths of a second.
Option Description
0No flow control
1 XON/XOFF flow control
3 RTS/CTS flow control (not a standard X.3 parameter)
Option Description
0 PAD prompt and signals disabled
1 PAD prompt disabled, signals enabled
4 PAD prompt enabled, signals disabled
5 PAD prompt enabled, signals disabled

Table of Contents