Configure X.25 parameters
Digi TransPort User Guide 559
CLR command: Clear an X.25 Call
The CLR command clears the current call and release the associated virtual channel for further
calls. On completion of call clear, the PAD> prompt is re-displayed. A call can also be cleared as a
result of a number of other situations. If one of these situations occurs, a message is issued to
the PAD in the following format:
CLR <Reason> C:<n> - <text>
where:
<Reason> is a 2/3 character clear down code
<n> is the numeric equivalent of the clear down code
<text> is a description of the reason for clear down
The clear down reason codes supported by the router are listed in the following table:
If an unknown reason code is received, the text field is blank.
Reason Code Numeric Code Text
DTE 0 by remote device
OOC 1 number busy
INV 3 invalid facility requested
NC 5 temporary network problem
DER 9 number out of order
NA 11 access to this number is barred
NP 13 number not assigned
RPE 17 remote procedure error
ERR 19 local procedure error
ROO 21 cannot be routed as requested
RNA 25 reverse charging not allowed
ID 33 incompatible destination
FNA 41 fast select not allowed
SA 57 ship cannot be contacted