Date and Time parameters
Digi TransPort User Guide 616
Related CLI commands
Entity Instance Parameter Values Equivalent Web Parameter
sntp n server Valid hostname or IP
address
sntp.timeserve.org
SNTP Server
sntp n pwrchk 0,1 Check on Power-up
0=Off
1=On
sntp n interval 0-255 Update every h hours
Default=24
sntp n randintsecs 0-86400 Randomly between s1 and s2
seconds
Use format [s1,s2]
For example, min 50, max 500
would be: [50,500]
sntp n offset -12 to +13 Offset from GMT.
sntp n dstonmon 0-12 Start: Month
Update for Daylight Saving Time
0 disables daylight saving.
sntp n dstonday 0-31 Start: Day
sntp n dstonhr 0-23 Start: Hour
sntp n dstoffmon 0-12 End: Month
sntp n dstoffday 0-31 End: Day
sntp n dstoffhr 0-23 End: Hour
sntp n ntp 0,1 0=SNTP
1=NTP
Default=OFF