Use the Analyser
Digi TransPort User Guide 758
Related CLI commands (not available via the Web Interface)
)
Entity Instance Parameter Values Description
ana 0 fcon on, off Enable serial flow control tracing.
ana 0 stopbufs 0-255 Stop analyser when number of free
system buffers matches this value.
ana 0 stopmsgs 0-255 Stop analyser when number of free
system messages matches this value.
ana 0 stopflood 0-1 Stop analyser when Ethernet flood
protection is activated.
ana 0 lowbufcmd Command
String
Run this command when the number
of free system buffers match
lowbuflvel.
ana 0 lowbuflev Integer Free system buffer threshold used by
lowbufcmd.
ana 0 lowmsgcmd Command
String
Run this command when the number
of free system messages match
lowmsglvel.
ana 0 lowmsglev Integer Free system message threshold used
by lowmsgcmd.
ana 0 logdrive String Specifies an alternate file system
drive on which to store the analyser
trace. To use an external USB flash
device, this should be set to u:
If the router has an internal SDIO
flash device, it can be selected with s:
ana 0 logfile Filename The file on the alternate drive to
which the analyser trace will be
stored.
ana 0 contfile Filename The file on the alternate drive to
which the analyser trace will be
stored once the file indicated by
logfile is reaches its max size as
specified by logsizek.
ana 0 logsizek Value in Kbytes The maximum size in Kbytes of the
file on the alternate drive.
When set to 0, the file size is only
limited by the flash device.