REFERENCE
5--36 27080 Issue 1 August 98
SERVICE
Provides access to printer functions for trained personnel.
Access to Service is controlled by
password (see pg. 2--13).
Enter the correct password and
select OK. (An incorrect password
must be removed using the delete
key before a revised password is
entered).
If the correct password is entered the screen changes to:
Provides general printer
information.
Ink Type : Shows the ink type in the printer.
Ink Temperature: Range: 5--55 C, depending upon ink type.
Target BFT: Dependent upon ink type (seconds).
Actual BFT: Result of last viscosity measurement
(seconds).
Reservoir Life: Normally 600 hours.
Reservoir Hours: Range: 0--600 hours remaining before
reservoir life expiry.
Head Temp: Range: 26--50 C depending upon ink type.
Ink Pressure: Range: 2500--3250 mbar depending upon ink
type.
Pinpoint Range: 3700--4500mbar depending
upon ink type
Pump Speed Range: 1700--2300 rpm depending upon ink
type.
Peltier Status: On/Off.
Mod’n Level: Range: 250--1850 x100mV depending upon
ink type, nozzle size.
Mode: Status: Fixed/Auto Set (fixed only on