REFERENCE
27080 Issue 1 August 98 5--39
Gutter State: Status: Wet/Dry.
Pump Speed: Range: 1700--2300 rpm depending upon ink
type.
Regulation: Status: Pressure/Vacuum/Disabled.
Target BFT: Dependent upon ink type (seconds).
Actual BFT: Result of last viscosity measurement
(seconds).
Ink Temp: Range: 5--55 C, depending upon ink type.
Mod’n Level: Range: 250--1850 x 100mV, depending upon
ink type.
Function key options:
Cancel Discard changes.
OK Accept new settings.
Sequence Off Sequences ink system to off.
Seq. to Standby Sequences ink system to standby.
Seq. to Jet Run Sequences ink system to jet running.
Seq. to Modulate Sequences ink system to modulating state.
Seq. to Phase LokSequences ink system to phase locked state.
Sequence On Sequences ink system fully on to Ready to
Print.
Fast Shutdown Emergency crash stop fast shutdown of ink
system. This shutdown does not flush the
head.
Reset Modulat’n Resets modulation according to current
criteria.
Bleed Head Bleeds print head.
Viscosity
Provides general ink and viscosity
information
Ink Type : Ink type in the printer.
Make--up: Make--up type in the printer.
Ink Temp : Range: 5--55 C, depending upon ink type.
Head Target: Range: 26--50 C gunbody target
temperature, dependant upon ink type.