APPENDIX B : A--SERIES AIR DRIVEN AIRDRYER
B--12 20951 Issue 1 Apr 98
The filters can now be replaced as follows:
(5) Replace the tubular bodied filter with a complete new item.
(6) Unscrew the glass bowl of the general and coalescing filters,
remove and clean.
(7) Unscrew the elements of the general and coalescing filters and
replace with new elements.
(8) Atthedryerhousingensurethatthetubesformingtheventsystem
are clean and free of residues.
(9) Replacethecompletefiltersetbyreversingsteps(2)to(4)ensuring
that all connections are tight.
Quickreleaseconnectorsareusedattheconnectionsofthetubestothe
bowlfilters. Todisconnecteachtube,releasetheconnector bypressing
thelocking ringandpulloffthetube(seediagram). Donotdisturbthe
screw thread connection of the connector into the filter body. To
reconnect the tube, push the tube firmly into the connector.
Press ring toward connector
Pull tube away from connector
Quick Release Connector
Locking Ring