EasyManua.ls Logo

DURKOPP ADLER 878-M PREMIUM - Parameter Selection (Parametercall) Submenu

DURKOPP ADLER 878-M PREMIUM
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming
66 Service Instructions 878-M PREMIUM - 03.0 - 10/2019
17.3 Parameter selection (ParameterCall) submenu
The submenu is visible only if the ParameterView parameter is active
(ParameterView)( p. 83). The settings for a parameter can be changed
directly here.
To change the parameters:
1. Select the menu Service > ParameterCall (Service > Parameter
selection).
2. Press the OK button to confirm the selection.
A window appears where the parameter can be selected:
Fig. 56: ParameterCall (Parameter selection) submenu
3. Select the level of the desired parameter with the / buttons.
4. Use the
button to move to the Cat category and select the desired
value with the
/ buttons or the number keys. The categories are
explained in the Parameter list 878-M PREMIUM.
5. Use the
button to move to the Par parameter and select the desired-
value with the
/ buttons or the number keys. The parameters are
explained in the Parameter list 878-M PREMIUM.
6. Use the
button to move to the fourth value on the far right. This value
may vary, depending on the parameter. It may be a mode or a window
with an action selection.
7. Enter the parameter value and confirm by pressing OK.
Abbreviation Meaning
O Operator
T Technician
+
ParameterCall
Cat Par Mode
01 00 6
T
Lvl

Table of Contents