5. Clean the area round the hydraulic oil tank, cap (1) and
breather filter (2).
6. Unscrew the cap and remove with filter element.
7.
We recommend to use our filling and filtering
unit with fine filter to fill the system. This
ensures finest filtration of the hydraulic oil,
prolongs the lifetime of the hydraulic oil filter
and protects the hydraulic system.
Fill up with fresh hydraulic oil.
8. Check the oil level in the inspection glass.
ð
Nominal value: Approx. 3 cm (1.2 in) below the top edge
of the inspection glass
9. Insert a new filter element (2) and new O-rings (1).
10. Screw the cap (1) back on.
11. Replace the breather filter (2).
12. After the test run, check the filters for leaks.
13. Dispose of the hydraulic oil and filter in line with environ-
mental regulations.
1
2
B-720-0058
Fig. 168
Hydraulic Oil
B-720-0061
Fig. 169
2
1
B-720-0087
Fig. 170
1
2
B-720-0058
Fig. 171
Maintenance – Every 2000 operating hours
D.ONE
132

Table of Contents