9.2 Teaching the BOSS safety field system
After replacing components in the radio communication system
(e.g. radio remote control, radio receiver) or BOSS safety field
system (e.g. aerial at the front or back), the BOSS safety field
system will need to be retaught.
Prerequisites:
n Main battery switch is switched on
n Emergency stop switch is unlocked
1. Remove the safety cap (1) and connect the cable (2) to the
remote control.
2. Take up position in the safety field at the machine.
ð
Distance: < 1.2 m (1.3 yd).
3. Turn the toggle switch for operating mode to the “left” posi-
tion.
4. Turn the ignition key to position “I”.
Fig. 185
Fig. 186
Fig. 187
Setting up / refitting – Teaching the BOSS safety field system
D.ONE