10.1 Starting the engine with jump leads
NOTICE!
A wrong connection will cause severe damage
in the electric system.
– Bridge the machine only with a 12 Volt auxiliary
battery.
1. Open the rear protective hood.
2. Switch on the main battery switch.
3. First connect the plus pole of the external battery to the plus
pole of the starter battery using the first jump lead.
4. Next, connect the second jump lead to the minus pole of the
energizing external battery and then to the minus pole of the
starter battery.
5.
Start the engine:
Ä
Chapter 6.2.4 „Starting the
engine“ on page 81.
6. After starting, disconnect the minus poles first and the plus
poles after.
7. Close the rear protective hood.
Fig. 193
Fig. 194
Troubleshooting – Starting the engine with jump leads
D.ONE
150