3.10 Emergency procedures
3.10.1 Actuating the emergency stop switch
In events of emergency and in case of danger actuate the emer-
gency stop switch immediately.
The machine is braked immediately; the engine is shut down.
Restart the machine only after the danger that caused the actua-
tion of the emergency stop switch has been eliminated.
3.10.2 Disconnecting the battery
In events of emergency, e.g. in case of a cable fire, disconnect the
battery from the vehicle network.
Pull out the main battery switch or lift off the battery pole to do so.
3.10.3 Recovering the machine
The machine can be recovered by lifting it out of the danger zone.
Loads may only be attached and hoisted by an expert/qualified
person.
Before lifting the machine, lock it with the articulation lock.
Do not use lifting points that are damaged or impaired in any way.
Use only lifting and lashing tackle with sufficient load bearing
capacity.
Fasten the lifting gear only at the specified lifting points.
Always use appropriate lifting and lashing tackle at the lifting
points.
Use lifting tackle only in the specified loading direction.
Lifting tackle must not be damaged by machine parts.
Danger to the life of persons if they step or stand under a sus-
pended load.
When lifting the machine, make sure the load does not move in an
uncontrolled way. If necessary, hold the load steady with guide
ropes.
Concerning your safety – Emergency procedures