EasyManua.ls Logo

Dynapac D.ONE - Faults in BOSS Safety System

Dynapac D.ONE
190 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10.8 Faults in BOSS safety system
Fault Possible cause Remedy
No travel move-
ments; steering is
still possible
The operator is inside the safety field with
radio remote control
Leave the safety field
Radio remote control or receiver replaced
and safety field system subsequently not
taught
Teach the safety field system
Ä
Chapter
9.2 „Teaching the BOSS safety field
system“ on page 146
Front or rear safety device aerial not con-
nected properly or defective
Check the plug-in connection of the aer-
ials; replace if necessary
Distance between machine and radio
remote control is too great
Reduce the distance
Safety device control not connected prop-
erly or defective
Check the plug-in connection of the con-
trol; replace if necessary
Radio remote control defective Have examined by a specialist; replace if
necessary
Wiring loom defective Have examined by a specialist; replace if
necessary
Troubleshooting – Faults in BOSS safety system
D.ONE
163

Table of Contents

Related product manuals