Fault Possible cause Remedy
Cable defective Check cable for tight fit
Have examined by a specialist; replace if
necessary
Remote control defective Have examined by a specialist; replace if
necessary
Control defective Have examined by a specialist; replace if
necessary
No function after
starting up engine
Start sequence not observed; engine
started before horn sounds
Actuate the warning horn button
Shut down the engine manually and
restart
Emergency stop switch actuated or
defective
Pull out the emergency stop switch
Have examined by a specialist; replace if
necessary
Remote control defective Have examined by a specialist; replace if
necessary
Cable defective Check cable for tight fit
Have examined by a specialist; replace if
necessary
Control defective Have examined by a specialist; replace if
necessary
"CTO" appears on
display module
when ignition key in
position "I"
Cable defective Check cable for tight fit
Have examined by a specialist; replace if
necessary
Control defective Have examined by a specialist
Engine does not
run to full speed
Engine speed toggle switch not actuated
or defective
Check the toggle switch position
Check the toggle switch signal, input
code 2505
Have examined by a specialist; replace if
necessary
Fuse F14 triggered Check the fuses; replace if necessary
Have examined by a specialist; replace if
necessary
Relay K114 defective Check the relay control signal, input code
5050
Have examined by a specialist; replace if
necessary
Control defective Have examined by a specialist; replace if
necessary
Cable defective Check cable for tight fit
Have examined by a specialist; replace if
necessary