6.1.2.3 Decrease in battery voltage
If the battery voltage drops too much during operation, the radio
operation control light goes red (approx. 10 minutes before the
machine stops).
If the battery voltage drops further, the warning buzzer sounds
additionally (approx. 1 minute before the machine stops).
If the remote control battery is empty, the machine stops and the
engine is switched off.
1. When the control light lights up, drive the machine to a safe
place and stop.
2. Remove the safety cap (1) and connect the cable (2) to the
remote control.
ð
The battery starts charging.
3. Switch to cable operation with the toggle switch.
4.
If the engine is off, restart the engine
Ä
Chapter 6.2.4
„Starting the engine“ on page 81.
5. Continue to operate the machine in cable mode.