MVX9000 Parameter Listing
MVX9000 User Manual B-9
Parameter Tables
Table B-4: 50 — DRIVE CONTROL (Continued)
Modbus Groups Page # Description Range Default
User
Settings
0334H 50.53 5-47 Auto Acceleration/
Deceleration
00: Linear Acceleration/
Deceleration
00
01: Auto Acceleration, Linear
Deceleration
02: Linear Acceleration/Auto
Deceleration
03: Auto Acceleration/
Deceleration
04: Auto Acceleration/
Deceleration Stall Prevention
(Limited by 50.12 to 50.15)
0335H 50.54 5-47 Sleep Frequency 0.0: Disabled 0.0
0.1 to 400 Hz Enabled
0336H 50.55 5-47 Wake Frequency 0.1 to 400 Hz (0.0 = Disable) 0.0
0337H 50.56 5-48 Sleep Time Delay 0.0 to 600 sec. 1.0
0338H 50.57 5-48 Second Source of
Master Frequency
00: Master Frequency
determined by digital keypad
up/down
00
01: Master Frequency
determined by keypad
potentiometer
02: Master Frequency
determined by 0 to +10V
input on AI terminal with
jumpers
03: Master Frequency
determined by 4 to 20 mA
input on AI terminal with
jumpers
04: Master Frequency
determined by RS-485
communication interface
0339H 50.58 5-48 Zero Speed Output
Selection
00: Standby
01: Zero Speed Output
00
033AH 50.59 5-49 Zero Speed Holding
Torque
0.0 to 30.0% 5.0%
033BH 50.60 5-49 Second Source of
Operation Command
00: Operation determined by
digital keypad
03
01: Operation determined by
external control terminals,
keypad STOP is effective
02: Operation determined by
external control terminals,
keypad STOP is ineffective
03: Operation determined by
RS-485 interface, keypad
STOP is effective
04: Operation determined by
RS-485 interface, keypad
STOP is ineffective
033CH 50.61 5-49 HOA and LOC/REM
Stop Methods
00: Ramp to Stop 01
01: Coast to Stop
033DH 50.62 5-49 OV Fault During Stop
State
00: Disable 00
01: Enable

Table of Contents