EDGECORE NETWORKS CORPORATION 2018
45
BDX_PECI_PCH
PECI_CPU detect
35
36
CPLD interrupt to CPU
CPLD_interrupt
PS_PWROK
PS_PWROK signal
from CPLD
37
38
All the power in the
chassis would be
reset when this pin is
0
All_power_reset
BDX_INTRUDER_N
INTRUDER#
function
39
40
All the power in the
chassis would be off
when this pin is 0
All_power_off
ID_LED status sense
ID_LED status sense
41
56
BCM5720 link indicator
BCM5720_link_status
PWRGD_P3V3_A
MB power status
sense
43
170
This pin is acted as
BMC push the RST
BTN.
1: nothing
0: active
RST_BTN_OUT_BMC_N
BDX_SPI_MUX_SEL
Controlled by BMC,
select the SPI bus host
is CPU or BMC
1: From CPU
0: From BMC
119
172
This pin is acted as
BMC push the PWR
BTN.
1: nothing
0: active
PWR_BTN_OUT_BMC_N
BMC_SPI_OUT_SEL
BMC select to CI flash
or KGI flash
1: CI
0: KGI
141
174
This pin is acted as
BMC generate the
NMI to CPU.
1: nothing
0: active
NMI_BTN_OUT_BMC_N
RST_BTN_IN_BMC_N
When the RST BTN
has been pushed,
BMC need to know
this action
169
176
This pin is acted as
BMC want to light on
the fault LED.
1: nothing
0: light on fault led
FAULT_LED_OUT_N
PWR_BTN_IN_BMC_N
When the RWR BTN
has been pushed,
BMC need to know
this action
171
178
This pin is acted as
BMC want to light on
the ID LED.
1: nothing
0: active
ID_LED_BMC_N
ID_BTN_BMC_N
When the ID BTN
has been pushed,
BMC need to know
173

Table of Contents

Other manuals for Edge-Core AS7326-56X

Related product manuals