Object name
Command Parameter
range
Factory
seng
Data type Units
Comments
Pump run
hours
?V862 0..65535 - decimal hours Hours run by pump
Temperature
readings 2
?V865 -200..200 - decimal °C Measured motor
temperature
-200..200 decimal °C Measured motor
controller temperature
-200..200 decimal °C Measured rotor
temperature
Factory
sengs
!S867 1 - - - Reset all conguraon
opons and parameters
to the factory sengs
PIC soware
version
?S868 10 - string chars Boot loader soware
version number
(D396596XXX)
Speed control !C869 0 - decimal - Set target speed to full
speed
1 - - - Set target speed to
standby speed
Timer opons !S870 0 1 decimal - Timer = disabled
?S870 1 - - - Timer = enabled
Note that the mer is
permanently enabled on
ramp-up.
Analogue
signal opons
!S871 0 0 decimal - Analogue output =
measured speed
?S871 1 - Analogue output =
measured power
2 Analogue output =
measured motor temp.
3 Analogue output =
measured control temp.
4 Analogue output =
measured rotor temp.
Electronic
braking
opons
!S872 0 0 decimal Electronic braking =
disabled
?S872 1 Electronic braking =
enabled. Refer to
Electronic braking on
page 14.