Cerabar M PMC51, PMP51, PMP55
Endress+Hauser 109
Product Configurator, "Output, Operation" ordering feature
Analog
on
off
Display
Zero
Span
damping
1
2
3
4
on
off
damping
1
A0032657
1 Operating keys for lower range value (zero), upper range value (span), position zero adjustment or reset
2 Green LED to indicate successful operation
3 Slot for optional local display
4 DIP switch for switching damping on/off
HART
on
off
Display
Zero
Span
HART
R
FIELD COM MUNICATION PROTO COL
SW / P2=High
delta p only
SW / Alarm min
SW /
damping
3
1
2
on
off
SW / P2=High
SW /
Alarm min
SW /
damping
1
2
3 4 5
8 7 6 5 4
A0032658
1 Operating keys for lower range value (zero) and upper range value (span)
2 Green LED to indicate successful operation
3 Slot for optional local display
4 DIP switch only for Deltabar M
5 DIP switch only for Deltabar M
6 DIP switch for alarm current SW / Alarm Min (3.6 mA)
7 DIP switch for switching damping on/off
8 DIP switch for locking/unlocking parameters relevant to the measured value