Device Functions Proline Promass 83 MODBUS RS485 3 Block MEASURED VARIABLES
Endress+Hauser 13
CARRIER MASS
FLOW
MODBUS register:
Data type:
Access:
0025
2035
Float
read
! Note!
Function is not available unless one of the following was selected:
in the function DENSITY FUNCTION (7000), see Page 125:
% MASS / % VOLUME
FLEXIBLE and in the function MODE (7021), see Page 127, the selection %
MASS 2D or % MASS 3D
The currently measured mass flow of the carrier fluid appears on the display.
Carrier fluid = transporting liquid (e.g. water).
Display: 5-digit floating-point number, including unit and sign
% CARRIER MASS
FLOW
MODBUS register:
Data type:
Access:
0026
2037
Float
read
! Note!
Function is not available unless one of the following was selected:
in the function DENSITY FUNCTION (7000), see Page 125:
% MASS / % VOLUME
FLEXIBLE and in the function MODE (7021), see Page 127, the selection %
MASS 2D or % MASS 3D
The currently measured mass flow of the carrier fluid is displayed as a % (of the
overall mass flow). Carrier fluid = transporting liquid (e.g. water).
Display: 5-digit floating-point number, including unit and sign
CARRIER VOLUME
FLOW
MODBUS register:
Data type:
Access:
0027
2039
Float
read
! Note!
Function is not available unless one of the following was selected:
in the function DENSITY FUNCTION (7000), see Page 125:
% MASS / % VOLUME
FLEXIBLE and in the function MODE (7021), see Page 127, the selection %
VOLUME 2D or % VOLUME 3D
The currently measured volume flow of the carrier fluid appears on the display.
Carrier fluid = transporting liquid (e.g. water).
Display: 5-digit floating-point number, including unit and sign
% CARRIER
VOLUME FLOW
MODBUS register:
Data type:
Access:
0028
2041
Float
read
! Note!
Function is not available unless % MASS / % VOLUME was selected in the
DENSITY FUNCTION function (7000), (see Page 125).
Use this function to display the currently measured corrected volume flow of the
carrier fluid. Carrier fluid = transporting liquid (e.g. water).
Display: 5-digit floating-point number, including unit and sign
CORRECTED
CARRIER VOLUME
FLOW
MODBUS register:
Data type:
Access:
0029
2043
Float
read
! Note!
Function is not available unless % MASS / % VOLUME was selected in the
DENSITY FUNCTION function (7000), (see Page 125).
The currently measured corrected volume flow of the carrier fluid appears on the
display.
Carrier fluid = transporting liquid (e.g. water).
Display: 5-digit floating-point number, including unit and sign