Device Functions Proline Promass 83 MODBUS RS485 10 Block SPECIAL FUNCTION
Endress+Hauser 157
10.3.6 Function group TEMPERATURE
SPECIAL FUNCTION H DENSITY FUNCTIONS HAA
BATCHING FUNCTION HCA
ADVANCED DIAGNOSTICS HEA CONFIGURATION 740
ACQUISITION 741
MASS FLOW 742
DENSITY 743
REFERENCE DENSITY 744
TEMPERATURE 745
Function description
SPECIAL FUNCTION ADVANCED DIAGNOSTICS TEMPERATURE
! Note!
The appropriate unit is taken from the function UNIT TEMPERATURE (0422), (see Page 18).
REFERENCE VALUE
MODBUS register:
Data type:
Access:
7450
See Note
Float
read
The reference value for the temperature appears on the display.
Display: 5-digit floating-point number, including units
! Note for MODBUS!
Depends on the option selected in the function SELECT REFERENCE
CONDITION:
•Option = FACTORY MODBUS register = 6605
•Option = USER MODBUS register = 6607
ACTUAL VALUE
MODBUS register:
Data type:
Access:
7451
6609
Float
read
The currently measured temperature appears on the display.
Display: 5-digit floating-point number, including units
MINIMUM VALUE
MODBUS register:
Data type:
Access:
7452
6611
Float
read
The lowest temperature value since the saved values were last reset appears on
the display.
Display: 5-digit floating-point number, including units
MAXIMUM VALUE
MODBUS register:
Data type:
Access:
7453
6613
Float
read
The highest temperature value since the saved values were last reset appears on
the display.
Display: 5-digit floating-point number, including units