5 Block USER INTERFACE Device Functions Proline Promass 83 MODBUS RS485
44 Endress+Hauser
5.3.2 Function group MULTIPLEX
USER INTERFACE C CONTROL CAA
MAIN LINE CCA
ADDITIONAL LINE CEA CONFIGURATION 240
MULTIPLEX 242
Function description
USER INTERFACE ADDITIONAL LINE MULTIPLEX
ASSIGN
MODBUS register:
Data type:
Access:
2420
2532
Integer
read/write
For assigning a second reading to be displayed in the main line alternately (every
10 seconds) with the value defined in the ASSIGN function (2400).
Options: standard
0 = OFF
1 = MASS FLOW
2 = MASS FLOW IN %
3 = VOLUME FLOW
4 = VOLUME FLOW IN %
5 = CORRECTED VOLUME FLOW
6 = CORRECTED VOLUME FLOW IN %
7 = DENSITY
8 = REFERENCE DENSITY
9 = TEMPERATURE
10 = MASS FLOW BARGRAPH IN %
11 = VOLUME FLOW BARGRAPH IN %
12 = CORRECTED VOLUME FLOW BARGRAPH IN %
15 = ACTUAL CURRENT
18 = ACTUAL FREQUENCY
20 = TOTALIZER 1
21 = TOTALIZER 2
22 = TOTALIZER 3
23 = TAG NAME
Factory setting: OFF
Advanced selection: with the optional SW package BATCHING
52 = BATCH NAME (“BATCH # 1” or “BEER 330”, etc.)
53 = BATCH QUANTITY (overall quantity to be batched)
54 = BATCH COUNTER (batching processes carried out)
55 = BATCH SUM (effective total batching quantity)
56 = BATCH UPWARDS (batching progress upwards)
57 = BATCH DOWNWARDS (batching progress downwards)
! Note!
The options given in the BATCHING software package always refer to the
batching selected in the function BATCH SELECTOR (“BATCH # 1”,
“BATCH # 2”, etc.). Example: If BATCH # 1 was selected in the BATCH
SELECTOR function (7200), then only the values from BATCH # 1 (batch name,
batch quantity etc.) can be displayed.
(continued on next page)