Maintenance 1. Safety Precautions on Maintenance
116 RC180 Rev.17
CAUTION
Do not touch the Motor Driver modules, Switching Power Supply, and
Regeneration Module directly in the Controller. T
he metal resistance of these
can become very hot
and may result in a burn. If you maintain them, examine
the surface temperature
s and wear protective gloves if necessary.
Do not shock, shake
, or drop any parts during maintenance. When the parts
related with data
are shocked physically, they may be damaged and may also
cause data loss during data loading/saving
.
Do not lose the screws removed at maintenance. When the screw is dropped
into the Controller, be sure to take it out. Leaving the screw in the
Controller
may cause short circuit and may result in equipment damage to the parts and/or
robot system.
Make sure that the
power rating (wattage) of a new Motor Driver module is
correct.
Using a Motor Driver module with improper power rating (wattage) in
the
Controller may cause improper function of the robot system and errors.
The serial number of the Manipulator that should be connected is indicated on
the
Connection Check Label on the Controller. Connect the Controller and the
Manipulator correctly.
Improper connection between the Controller and the
Manipulator may cause not only improper function of the robot system but also
serious safety problems.
Before performing maintenance on the Controller, all the data must be copied as a backup.
The details of data backup/restore are described in the Maintenance 4. Backup and
Restore.
1.2 Lockout / Tagout
Lockout / tagout is a method to prevent any one from turning ON the robot system by
mistake while someone else is within the safeguarded area for maintenance or repair.
When performing maintenance and repair, lockout and tagout using the following
procedure.
(1) Turn OFF the POWER switch.
(2) Secure the POWER switch mounting metal hasp in the POWER switch OFF position
with screws.
POWER Switch
Mounting Metal Hasp
POWER Switch
(3) Unplug the power supply plug of the Controller from the power supply socket.
(4) Attach a note to the POWER switch or the power supply plug to prevent any one from
turning ON the robot system by mistake.
RC180-UL:
For maintenance and repair, make sure to lockout and tagout the external disconnecting
means.
NOTE

Table of Contents

Other manuals for Epson RC180

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson RC180 and is the answer not in the manual?

Epson RC180 Specifications

General IconGeneral
BrandEpson
ModelRC180
CategoryController
LanguageEnglish

Related product manuals