4. Backup and Restore
4.1 What is the Backup Controller Function?
The controller configuration set by EPSON RC+ 5.0 can be stored with the “Backup
Controller” function.
The Controller settings can be restored easily using the data previously stored with
Backup Controllerafter a configuration mistake or Controller problem.
Be sure to execute Backup Controller before changing the Controller setup, before
maintenance, or after teaching.
For some problems, backup may not be available before maintenance has to be performed.
Be sure to backup the data after making changes, before problems occur.
Controller Status Storageis one of the RC180 functions. It saves the Controller setup
data the same as with Backup Controller,and additional data such as the Controller
status.
There data can be used as the backup data at restoring.
The methods for Controller Status Storage” are as follows:
A : Controller status storage to USB memory
For details, refer to Setup & Operation 6. Memory Port.
B : “Export Controller Status function” in EPSON RC+ 5.0.
For details, refer to EPSON RC+ 5.0 Users Guide 5.9.9 Import Command (Project
Menu).
4.2 Backup Data Types
The table below shows the files created with Backup Controller”.
File Name
Overview
Backup.txt
Information file for
restore
File including information for restoring
the Controller.
CurrentMnp01.PRM
Robot parameters
Stores information such as TlSet.
InitFileSrc.txt
Initial configuration
Stores various Controller parameters.
MCSys01.MCD
Robot configuration
Stores connected Robot information.
All the files related
to Project *
Project related All the project files transferred to the
Controller. Includes program files when
EPSON RC+ 5.0 is configured to transfer
source code to the Controller.
GlobalPreserves.dat
*
Global Preserve
variables
Saves values of Global Preserve
variables.
* If the version of the Controller firmware is Ver.1.0.*.*, project related data and
GlobalPreserves.dat are not stored.
NOTE

Table of Contents

Other manuals for Epson RC180

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson RC180 and is the answer not in the manual?

Epson RC180 Specifications

General IconGeneral
BrandEpson
ModelRC180
CategoryController
LanguageEnglish

Related product manuals