Maintenance 6. Maintenance Parts Replacement Procedures
160 RC180 Rev.17
(7)
Pull out the DPB cable connector (CN1)
and remove the intermediate plate.
CN1
Fuse
(8)
Pull out
the fuse in direction of the arrow.
Pull the wires to
the side to allow
clearance for pulling out the fuse.
Fuse
Mount
(1)
Hold the intermediate plate to connect the DPB cable connector (CN1).
(2)
Mount the intermediate plate to the Controller and secure the four mounting screws
and
the FG mounting screws (G / RS: 2 screws, C3 / S5: 3 screws) removed in steps
(5) and (6).
Be sure to keep the cable from being trapped or damaged.
(3)
Mount
the Motor Driver Module.
Refer :
Maintenance 6.3.2 Replacing Motor
(4)
Mount
the fan unit.
Refer :
Maintenance 6.1.2 Replacing Fan Unit
(5)
Mount the Option Unit when it was installed.
Refer :
Maintenance 6.7.2 Mount Option Unit 1
Maintenance 6.7.6 Mount Option Unit 1, 2
(6)
Plug in
the power connector. Turn ON the Controller and make sure that the
Controller starts properly without any vibration or abnormal noise.
NOTE
NOTE

Table of Contents

Other manuals for Epson RC180

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson RC180 and is the answer not in the manual?

Epson RC180 Specifications

General IconGeneral
BrandEpson
ModelRC180
CategoryController
LanguageEnglish

Related product manuals